# CMC 15032 – Technical Data Sheet

> 15032

[PDF data sheet (binding)](/pdf/cmc-15032-en.pdf) · [Deutsche Version](/cmc-15032-de.md)

Issued: 2016-01

## Product description

One-side adhesive, thermally insulating silicone film for the thermal connection of diodes, rectifiers and electronic modules, for example, in automotive applications, in solar technology or motor controls.

| Property | Value |
|---|---|
| Supporting Base | Ceramic filled silicone |
| Reinforcement | Fibreglass |
| Colour | Green |
| Substrate thickness in mm | 0.23 |
| Total thickness in mm | 0.28 |

## Adhesive Properties

| Property | Value |
|---|---|
| Adhesive strength in N/cm according to internal method PV 1006-32 (180° peel from steel) | ≥3 |

## Thermal properties

| Property | Value |
|---|---|
| Thermal conductivity in W /mK (for the ceramic filled silicone) | 3.0 |
| Flammability according to UL 94 | V0 |
| Temperature range in °C | -50 up to +200 |

## Electrical properties

| Property | Value |
|---|---|
| Dielectric strength in kV AC | 4.2 |
| Volume resistivity in ohm x cm | > 1011 |

## Other properties

- one-side adhesive - very good thermal contact - high mechanical stability - extraordinary chemical resistance and long-term stability - residue-free removal after use

---

*The technical data are average values and do not replace the user's own testing. Subject to change without notice. The PDF data sheet is binding.*