type: "Technical Data Sheet"
title: "MP 7023-002A – Preliminary Technical Data Sheet"
description: "MP 7023-002A: Kapton® HN (polyimide), brown / amber, 0.025 (nominal), acrylic"
resource: "https://datasheets.cmc.de/pdf/mp-7023-002a-en.pdf"
tags: ["kapton® hn (polyimide)", "0.025 (nominal)", "acrylic"]
language: "en"
product: "MP 7023-002A"
product_family: "mp"
document_date: "2023-11"
status: "draft"
generated: { by: "process:cmc-datasheets/0.1.0", at: "2026-09-23T16:55:33Z" }
sources:
  - id: "pdf"
    resource: "https://datasheets.cmc.de/pdf/mp-7023-002a-en.pdf"
    title: "Preliminary Technical Data Sheet MP 7023-002A"
    author: "CMC Klebetechnik GmbH"
    last_modified: "2023-11-23T12:59:54Z"
---

# MP 7023-002A – Preliminary Technical Data Sheet

> Product construction MP 7023-002A is a double layer Kapton® insulating tape.

[PDF data sheet (binding)](/pdf/mp-7023-002a-en.pdf)

Issued: 2023-11

## General data

| Property | Value |
|---|---|
| Backing material | Kapton® HN (polyimide) |
| Colour | brown / amber |
| Substrate thickness (single layer) in mm | 0.025 (nominal) |
| Total thickness in mm | 0.110 ± 10% |

## Adhesive properties

| Property | Value |
|---|---|
| Type of adhesive | acrylic |
| Adhesive thickness (single layer) in mm | 0.030 (nominal) |
| Adhesive strength in N/cm according to internal method PV 1006-32 (180° peel from steel) | ≥2 |

## Thermal properties

| Property | Value |
|---|---|
| Temperature performance in °C | 180 |
| Insulation class according to IEC 60085 | H |

## Electrical properties

| Property | Value |
|---|---|
| Breakdown voltage based on IEC 60243-1 in Veff. | ≥ 10'500 |

## Mechanical properties

| Property | Value |
|---|---|
| Tensile strength in N/cm | ≥ 100 |
| Elongation at break in % | ≥ 50 |

## Other properties

| Property | Value |
|---|---|
| Liner | siliconized paper |

® registered trademark of DuPont de Nemours

| Property | Value |
|---|---|
| Recommended storage cond.: cool and dry (15 - 25°C, < 65% rel. humidity) | 11/23 |

---

*The technical data are average values and do not replace the user's own testing. Subject to change without notice. The PDF data sheet is binding.*